You are installing a new SC9000. Which procedure should be used to install and configure the
system?
Select the answer
1 correct answer
A.
Connect through the iDRAC port
B.
Connect through a null modem cable to the serial port
C.
Connect through the Dell Storage Manager Client
D.
Connect through the supplied proprietary serial cable to the serial port

Quiz

2/10
Based on SAS back-end cabling best practices, which configuration represents how an SC4020 storage
array with one SC220 expansion enclosure is cabled?
Certification Exam DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Dell-EMC Dell-EMC-DES-1721 1-2766503211


Certification Exam DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Dell-EMC Dell-EMC-DES-1721 2-3659946637


Certification Exam DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Dell-EMC Dell-EMC-DES-1721 3-487755414
Select the answer
1 correct answer
A.
Configuration A
B.
Configuration B
C.
Configuration C
D.
Configuration D

Quiz

3/10
An administrator wants to configure an SC Series array to use Virtual Port Mode. What is a
requirement to accomplish this task?
Select the answer
1 correct answer
A.
NPIV must be disabled on Fibre Channel switches
B.
I/O Controller cards must use a single-ID firmware version
C.
Fibre Channel switches must use a switched fabric topology
D.
Activation license must be purchased and installed

Quiz

4/10
What are the possible methods to upgrade the firmware on a Brocade switch?
Select the answer
1 correct answer
A.
FTP, SFTP, and Web Tools
B.
USB, FTP, and SFTP
C.
USB, FTP, and Web Tools
D.
USB, SFTP, and Web Tools

Quiz

5/10
A customer is running the Dell Storage Manager (DSM) Suite as a software stack on Microsoft
Windows. To reduce the Microsoft licensing costs, the customer wants to switch to the DSM Virtual
Appliance.
Which recommended deployment should the customer use?
Select the answer
1 correct answer
A.
Configure as a Primary Data Collector
B.
Configure as a Remote Data Collector
C.
Migrate the DSM database manually
D.
Migrate from the existing Data Collector

Quiz

6/10
Which operating system runs the Dell Storage Manager (DSM) as a virtual appliance?
Select the answer
1 correct answer
A.
CentOS 7
B.
Windows Server 2012 R2
C.
VMware
D.
Windows Server 2010 R2

Quiz

7/10
Which best practices should be followed when using iSCSI to connect SC Series arrays and hosts for
switches that incorrectly negotiate speed and duplex?
Select the answer
1 correct answer
A.
Use a separate supernet or switches for iSCSI trafficGigabit full duplex hard set for all iSCSI portsEnsure switches used for iSCSI are of a blocking design
B.
Use a separate VLAN or switches for iSCSI trafficAuto-negotiate for all switchesEnsure switches used for iSCSI are of a non-blocking design
C.
Use a separate VLAN or switches for iSCSI trafficGigabit full duplex hard set for all iSCSI portsEnsure switches used for iSCSI are of a non-blocking design
D.
Use a separate subnet or switches for iSCSI trafficAuto-negotiate for all switchesEnsure switches used for iSCSI are of a blocking design

Quiz

8/10
DRAG DROP


What is the correct system hierarchy of SC Series array storage virtualization?

Certification Exam DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Dell-EMC Dell-EMC-DES-1721 4-3093089763
Select the answer
1 correct answer
The correct system hierarchy of SC Series array storage virtualization is:

1. Volume
2. Virtual disk
3. Storage tier
4. Disk folder
5. Physical disk

Why this is the correct order:

- Volume
A volume is the top-level storage object presented to hosts. It is the logical unit that applications and servers consume.

- Virtual disk
The volume is placed on a virtual disk. In SC Series, a virtual disk is a logical container that abstracts the underlying physical drives.

- Storage tier
Virtual disks are associated with a storage tier. Tiers group disks by performance characteristics, such as SSD, performance, or capacity.

- Disk folder
A disk folder is a grouping mechanism beneath the tier level that helps organize physical disks.

- Physical disk
At the bottom of the hierarchy are the actual physical drives that store the data.

In SC Series storage virtualization, the hierarchy moves from the logical object used by hosts down through layers of abstraction until it reaches the physical media. This allows the system to automatically manage placement, performance, and data distribution across different types of disks.

So the correct answer is A.

Quiz

9/10
Assume a storage administrator is using the recommended storage profile. What describes the
distribution of volume data residing in an SC series storage array that has 15K and 7K as the back-
end?
Select the answer
1 correct answer
A.
New and frequently accessed replay data in Tier 1 RAID 5Aged replay data and inaccessible data in Tier 3 RAID 6
B.
New data in Tier 1 RAID 10Frequently accessed replay data in Tier 1 RAID 5Aged replay data and inaccessible data in Tier 3 RAID 6
C.
New data in Tier 1 RAID 10Frequently accessed replay data in Tier 2 RAID 5Aged replay data and inaccessible data in Tier 3 RAID 6
D.
New and frequently accessed replay data in Tier 1 RAID 10Aged replay data and inaccessible data in Tier 3 RAID 6

Quiz

10/10
A customer is facing poor performance on all synchronously replicated volumes every Thursday
between 4 PM and 6 PM. All departments have checked their applications for any batch jobs;
however, nothing was found. The I/O graphs do not show any anomaly and the replication links are
not saturated.
What is the possible reason for this behavior?
Select the answer
1 correct answer
A.
Switches used for replication are restarting
B.
QoS Bandwidth Limit is enabled in the QoS node
C.
Data Progression is consuming all disk performance
D.
Automatic report creation is impacting replication
Looking for more questions?Buy now

DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Practice test unlocks all online simulator questions

Thank you for choosing the free version of the DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series practice test! Further deepen your knowledge on Dell-EMC Simulator; by unlocking the full version of our DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Simulator you will be able to take tests with over 147 constantly updated questions and easily pass your exam. 98% of people pass the exam in the first attempt after preparing with our 147 questions.

BUY NOW

What to expect from our DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series practice tests and how to prepare for any exam?

The DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Simulator Practice Tests are part of the Dell-EMC Database and are the best way to prepare for any DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series exam. The DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series practice tests consist of 147 questions and are written by experts to help you and prepare you to pass the exam on the first attempt. The DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series database includes questions from previous and other exams, which means you will be able to practice simulating past and future questions. Preparation with DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Simulator will also give you an idea of the time it will take to complete each section of the DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series practice test . It is important to note that the DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Simulator does not replace the classic DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series study guides; however, the Simulator provides valuable insights into what to expect and how much work needs to be done to prepare for the DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series exam.

BUY NOW

DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Practice test therefore represents an excellent tool to prepare for the actual exam together with our Dell-EMC practice test . Our DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Simulator will help you assess your level of preparation and understand your strengths and weaknesses. Below you can read all the quizzes you will find in our DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Simulator and how our unique DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Database made up of real questions:

Info quiz:

  • Quiz name:DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series
  • Total number of questions:147
  • Number of questions for the test:50
  • Pass score:80%

You can prepare for the DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series exams with our mobile app. It is very easy to use and even works offline in case of network failure, with all the functions you need to study and practice with our DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Simulator.

Use our Mobile App, available for both Android and iOS devices, with our DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Simulator . You can use it anywhere and always remember that our mobile app is free and available on all stores.

Our Mobile App contains all DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series practice tests which consist of 147 questions and also provide study material to pass the final DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series exam with guaranteed success. Our DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series database contain hundreds of questions and Dell-EMC Tests related to DES-1721: Dell EMC Specialist - Implementation Engineer, SC Series Exam. This way you can practice anywhere you want, even offline without the internet.

BUY NOW