The new flashcard feature is useful to memorize questions.
?Change your study mode
At any time, you can change the study mode, and alternate between the practice mode and the exam mode. In practice mode, you can configure for example the number of questions or tests, and other parameters to help you study.
Randomized | 10 Questions per Test | 20 Minutes | 70% to pass|
To re-configure your study mode again and change - for example - the number of tests, whether you have random questions and all other configuration parameters.
?Simulator Configuration
Auto-scroll: You can use the automatic scrolling of the questionnaire that occurs as soon as you answer one or all of the answers to a question correctly. Auto scrolling is activated if you answer a single answer, or as soon as you answer all the mandatory answers. Learning Mode: During learning mode you can get a real time result for your answer.
Free Test
Question: / 10
20:00Min. left
?Restart the current test
To restart the current test by clearing all your answers and the time used up to now. Warning: all answers will be lost.
Question: / 10
4.7(119 Votes)
Quiz
Question 1/101/10
Annual testing for a 1,500 gpm (5,677 L/min) at 80 psi (1.4 bar) fire pump supporting an attached sprinkler system demand of 1,800 gpm (6,813 L/min) at 100 psi (6.9 bar) is being conducted. The flow test of the fire pump must achieve what minimum flow rate and discharge pressure?
Select the answer:Select the answer
1 correct answer
A.
1,500 gpm (5,677 L/min) at 80 psi (1.4 bar)
B.
1,600 gpm (6,056 L/min) at 75 psi (5.1 bar)
C.
1,800 gpm (6,813 L/min) at 100 psi (6.9 bar)
D.
2,250 gpm (8,516 L/min) at 65 psi (4.5 bar)
For annual testing of fire pumps, NFPA standards require the pump to be tested at its rated capacity and pressure, as well as at 150% of its rated capacity at a correspondingly lower pressure. In this scenario, the minimum flow rate required for the test is the demand of the attached sprinkler system, which is 1,800 gpm at 100 psi, to ensure the pump can meet or exceed the system's highest demand. Reference: NFPA 13, NFPA 20, and CWBSP materials provide guidance on fire pump testing, indicating that pumps should be tested for both rated and excess capacities to ensure they can handle the required system demand.
Right Answer: C
Quiz
Question 2/102/10
If a jockey pump start point is set at 165 psi (11.4 bar), the jockey pump stop point should be not less than
Select the answer:Select the answer
1 correct answer
A.
130 psi (8.96 bar).
B.
153 psi (10.55 bar).
C.
175 psi (12.06 bar).
D.
188 psi (12.96 bar).
The jockey pump stop point is typically set slightly above the fire pump start point to prevent unnecessary cycling of the fire pump. If the jockey pump start point is at 165 psi, the stop point should be higher to maintain system pressure and prevent overlap with the fire pump activation threshold, making 175 psi a suitable stop point. Reference: NFPA 20 and CWBSP materials, which cover the installation and testing of fire pumps, including jockey pumps, recommend setting the jockey pump's stop pressure above its start pressure to ensure seamless system pressure maintenance.
Right Answer: C
Quiz
Question 3/103/10
Which of the following is a mandatory referenced publication in NFPA 13?
Select the answer:Select the answer
1 correct answer
A.
NFPA 10
B.
NFPA 12
C.
NFPA 20
D.
NFPA 291
NFPA 20, which covers the installation of stationary pumps for fire protection, is a mandatory reference in NFPA 13. This standard is essential for ensuring that fire pumps, which are critical components of many sprinkler systems, meet the necessary performance and installation criteria. Reference: NFPA 13 references NFPA 20 as a key standard for the design and installation of fire pump assemblies, ensuring they provide adequate pressure and flow for sprinkler systems.
Right Answer: C
Quiz
Question 4/104/10
The distance between a hanger and the center line of an upright sprinkler shall be no less than
Select the answer:Select the answer
1 correct answer
A.
3 in. (75 mm).
B.
4 in. (100 mm).
C.
5 in. (125 mm).
D.
6 in. (150 mm).
The correct answer is: A . 3 in. (75 mm) This information can be found in several NFPA standards related to sprinkler systems, including: • NFPA 13, Standard for the Installation of Sprinkler Systems, 2022 edition (Section 9.2.3.4) • NFPA 13D, Standard for the Installation of Sprinkler Systems in One- and Two-Family Dwellings and Manufactured Homes, 2022 edition (Section 8.2.3.4) • NFPA 13R, Standard for the Installation of Sprinkler Systems in Low-Rise Residential Occupancies, 2022 edition (Section 9.2.3.4) These standards all mandate a minimum clearance of 3 inches (75 mm) between the hanger and the centerline of an upright sprinkler to ensure the sprinkler's unimpeded operation and discharge pattern in case of a fire. It's important to note that other standards with different requirements might exist, so it's always best to consult the specific NFPA standard relevant to your situation for accurate information. Additionally, always adhere to local codes and regulations when working with fire protection systems.
Right Answer: A
Quiz
Question 5/105/10
When backflow prevention valves are installed on existing pipe scheduled systems, the friction losses of the device shall be accounted for when determining
Select the answer:Select the answer
1 correct answer
A.
residual pressure.
B.
system flow requirements.
C.
static pressure.
D.
system GPM requirements.
When backflow prevention devices are added to a system, their associated friction losses can affect the residual pressure available for the sprinkler system operation. Therefore, it's important to account for these losses to ensure the system maintains the required pressure during operation. Reference: NFPA 13 includes considerations for the installation of backflow preventers and their impact on system design, emphasizing the need to account for device-related friction losses to maintain adequate residual pressure in the sprinkler system.
Right Answer: A
Quiz
Question 6/106/10
Based on an existing hydraulic placard located at the sprinkler system riser, the design of the sprinkler system is based on a density of 0.495 gpm/ft2 (20.1 mm/min) over an area of 2000 ft2 (186 m2). Sprinklers in cabinet are 286 degrees. Which of the following hazards can be protected with this design criteria?
Select the answer:Select the answer
1 correct answer
A.
Class IlI encapsulated commodity stored on single and double row racks to a storage height of 22 ft (4.9 m).
B.
Class IV nonencapsulated commodity stored on single and double row racks to a storage height of 20 ft (6.1 m) with 8 ft (2.4 m) aisles.
C.
Group A nonexpanded plastic stored in stable piles to a maximum height of 15 ft (4.6 m) in a 25 ft (7.6 m) high building.
D.
Group A plastic stored on single and double row racks to a maximum height of 15 ft (4.6 m) in a 25 ft (7.6 m) high building.
Group A plastics, even when stored on racks, present a high challenge to sprinkler systems due to their high heat release rates. The given design criteria, especially the density of 0.495 gpm/ft² over an area of 2000 ft², might be suitable for controlling fires in Group A plastic commodities stored to the specified height, considering the use of high-temperature rated sprinklers (286 degrees) which are typically used in high-challenge fire scenarios.
Right Answer: D
Quiz
Question 7/107/10
A sprinkler system has been installed with 100 sprinklers. What is the minimum number of spare sprinklers to be provided?
Select the answer:Select the answer
1 correct answer
A.
3
B.
6
C.
9
D.
12
According to NFPA 13, a supply of at least six spare sprinklers shall be maintained on the premises for facilities having under 300 sprinklers. Since the sprinkler system has been installed with 100 sprinklers, the minimum number of spare sprinklers to be provided is six. Reference: NFPA 13, 2019 edition, section 16.2.7.5(1)1; NFPA 13 Handbook, 2019 edition, section 16.2.7.5(1)2 1: https://www.nfpa.org/codes-and-standards/all-codes-and-standards/list-of-codes-and- standards/detail?code=13 2: https://www.nfpa.org/product/nfpa-13-handbook/p0013hb
Right Answer: B
Quiz
Question 8/108/10
What is the hose stream allowance and duration for rolled paper storage protected using ESFR sprinklers?
Select the answer:Select the answer
1 correct answer
A.
250 gpm (950 L/min) for 60 minutes
B.
250 gpm (950 L/min) for 180 minutes
C.
500 gpm (1900 L/min) for 120 minutes
D.
500 gpm (1900 L/min) for 180 minutes
ESFR (Early Suppression, Fast Response) sprinklers are designed for high-challenge fire hazards like rolled paper storage. The hose stream allowance for such systems is typically higher to account for the potential need for manual firefighting assistance. 500 gpm for 120 minutes provides a substantial water supply for this purpose. Reference: Based on NFPA 13's guidelines for storage and ESFR sprinkler systems.
Right Answer: C
Quiz
Question 9/109/10
What is the pressure at a sprinkler head with a flow of 33 gpm (125 L/min) with a K-factor of 5.6 (80)?
Select the answer:Select the answer
1 correct answer
A.
15.2 psi (1.1 bar)
B.
22.3 psi (1.54 bar)
C.
34.7 psi (2.4 bar)
D.
54.8 psi (3.78 bar)
The pressure at a sprinkler can be calculated using the formula P=Q²/K², where P is the pressure in psi, Q is the flow rate in gpm, and K is the K-factor of the sprinkler. Substituting the given values (Q=33 gpm, K=5.6) yields a pressure of approximately 22.3 psi. Reference: Basic hydraulic principles applied in the design and analysis of sprinkler systems as outlined in NFPA 13.
Right Answer: B
Quiz
Question 10/1010/10
The purpose of the owner's certificate is to
Select the answer:Select the answer
1 correct answer
A.
help ensure that the capability of the sprinkler system is adequate to address the hazard.
B.
replace project plans.
C.
obtain the building permit.
D.
be a declaration by the sprinkler contractor as to the hazards in the building.
The owner’s certificate is a form that the owner or the owner’s representative fills out to provide information about the property, the intended use of the building, the existing or planned construction, and the presence of any special materials, occupancies, or hazards. The purpose of the owner’s certificate is to help ensure that the capability of the sprinkler system is adequate to address the hazard and that the design and installation of the fire sprinkler system are based on accurate and complete information. The owner’s certificate is not intended to replace project plans, obtain the building permit, or be a declaration by the sprinkler contractor as to the hazards in the building. Reference: Owner’s Information Certificate; NFPA 13: Standard for the Installation of Sprinkler Systems; NFPA 13 Handbook
CWBSP: NFPA Certified Water-Based Systems Professionals Practice test unlocks all online simulator questions
Thank you for choosing the free version of the CWBSP: NFPA Certified Water-Based Systems Professionals practice test! Further deepen your knowledge on NFPA Simulator; by unlocking the full version of our CWBSP: NFPA Certified Water-Based Systems Professionals Simulator you will be able to take tests with over 100 constantly updated questions and easily pass your exam. 98% of people pass the exam in the first attempt after preparing with our 100 questions.
What to expect from our CWBSP: NFPA Certified Water-Based Systems Professionals practice tests and how to prepare for any exam?
The CWBSP: NFPA Certified Water-Based Systems Professionals Simulator Practice Tests are part of the NFPA Database and are the best way to prepare for any CWBSP: NFPA Certified Water-Based Systems Professionals exam. The CWBSP: NFPA Certified Water-Based Systems Professionals practice tests consist of 100 questions and are written by experts to help you and prepare you to pass the exam on the first attempt. The CWBSP: NFPA Certified Water-Based Systems Professionals database includes questions from previous and other exams, which means you will be able to practice simulating past and future questions. Preparation with CWBSP: NFPA Certified Water-Based Systems Professionals Simulator will also give you an idea of the time it will take to complete each section of the CWBSP: NFPA Certified Water-Based Systems Professionals practice test . It is important to note that the CWBSP: NFPA Certified Water-Based Systems Professionals Simulator does not replace the classic CWBSP: NFPA Certified Water-Based Systems Professionals study guides; however, the Simulator provides valuable insights into what to expect and how much work needs to be done to prepare for the CWBSP: NFPA Certified Water-Based Systems Professionals exam.
CWBSP: NFPA Certified Water-Based Systems Professionals Practice test therefore represents an excellent tool to prepare for the actual exam together with our NFPA practice test . Our CWBSP: NFPA Certified Water-Based Systems Professionals Simulator will help you assess your level of preparation and understand your strengths and weaknesses. Below you can read all the quizzes you will find in our CWBSP: NFPA Certified Water-Based Systems Professionals Simulator and how our unique CWBSP: NFPA Certified Water-Based Systems Professionals Database made up of real questions:
Info quiz:
Quiz name:CWBSP: NFPA Certified Water-Based Systems Professionals
Total number of questions:100
Number of questions for the test:50
Pass score:80%
You can prepare for the CWBSP: NFPA Certified Water-Based Systems Professionals exams with our mobile app. It is very easy to use and even works offline in case of network failure, with all the functions you need to study and practice with our CWBSP: NFPA Certified Water-Based Systems Professionals Simulator.
Use our Mobile App, available for both Android and iOS devices, with our CWBSP: NFPA Certified Water-Based Systems Professionals Simulator . You can use it anywhere and always remember that our mobile app is free and available on all stores.
Our Mobile App contains all CWBSP: NFPA Certified Water-Based Systems Professionals practice tests which consist of 100 questions and also provide study material to pass the final CWBSP: NFPA Certified Water-Based Systems Professionals exam with guaranteed success.
Our CWBSP: NFPA Certified Water-Based Systems Professionals database contain hundreds of questions and NFPA Tests related to CWBSP: NFPA Certified Water-Based Systems Professionals Exam. This way you can practice anywhere you want, even offline without the internet.