The new flashcard feature is useful to memorize questions.
?Change your study mode
At any time, you can change the study mode, and alternate between the practice mode and the exam mode. In practice mode, you can configure for example the number of questions or tests, and other parameters to help you study.
Randomized | 10 Questions per Test | 20 Minutes | 70% to pass|
To re-configure your study mode again and change - for example - the number of tests, whether you have random questions and all other configuration parameters.
?Simulator Configuration
Auto-scroll: You can use the automatic scrolling of the questionnaire that occurs as soon as you answer one or all of the answers to a question correctly. Auto scrolling is activated if you answer a single answer, or as soon as you answer all the mandatory answers. Learning Mode: During learning mode you can get a real time result for your answer.
Free Test
Question: / 10
20:00Min. left
?Restart the current test
To restart the current test by clearing all your answers and the time used up to now. Warning: all answers will be lost.
Question: / 10
4.9(111 Votes)
Quiz
Question 1/101/10
What must be installed on a guest VM prior to enabling Self-Service Restore?
Select the answer:Select the answer
1 correct answer
A.
Post_Thaw Scripts
B.
NGT
C.
Pre_Freeze Scripts
D.
VirtIO
The correct answer is B. NGT. Self-Service Restore requires Nutanix Guest Tools (NGT) to be installed on the guest VM before the feature can be enabled. NGT provides the guest-side integration needed for management functions such as guest customization, shutdown/reboot operations, and restore-related capabilities. Why the other options are incorrect: A. Post_Thaw Scripts These are not required for enabling Self-Service Restore. They are typically used for backup or recovery workflows, not as a prerequisite for the feature itself. C. Pre_Freeze Scripts These are also related to backup consistency operations, especially for application-aware snapshots, but they are not required for Self-Service Restore. D. VirtIO VirtIO drivers help improve performance for certain virtual devices, especially on Linux guests, but they are not the required component for enabling Self-Service Restore. In short, NGT must be installed because it is the guest agent that enables self-service management and restore functionality.
Right Answer: B
Quiz
Question 2/102/10
During routine monitoring, an administrator notices that replication from the primary Nutanix cluster to the recovery cluster has stopped. New recovery points are not being created, and the DR dashboard shows replication errors. Investigation reveals: The primary and recovery clusters are both online and healthy. Network segmentation was recently enabled to isolate replication traffic from other workloads. No recent changes were made to firewall rules, protection policies or RPO settings. Which action should the administrator take first to investigate the replication failure?
Select the answer:Select the answer
1 correct answer
A.
Delete and recreate the protection policy to reset replication.
B.
Increase the RPO interval setting in order to reduce the replication load.
C.
Verify required ports are open and reachable between clusters.
D.
Perform a test failover at the recovery site.
The correct answer is B, but there is an inconsistency in the question and the answer choices. Why this is inconsistent: The scenario says replication has stopped, new recovery points are not being created, and the DR dashboard shows replication errors. It also says network segmentation was recently enabled to isolate replication traffic. In that context, the first thing an administrator should normally investigate is connectivity between the clusters, especially required ports and routing. That would make C the most logical first action: C. Verify required ports are open and reachable between clusters. Why C makes sense: Replication between Nutanix clusters depends on network connectivity and the required replication ports being accessible. Since the only recent change mentioned is network segmentation, the most likely cause is that replication traffic is now being blocked or isolated incorrectly. Before changing any DR settings, the admin should confirm: - the clusters can reach each other - the necessary ports are open - routing between source and destination is correct - any segmentation or ACL rules are not blocking replication traffic Why the other options are less appropriate: A. Delete and recreate the protection policy to reset replication. This is too disruptive and not the first troubleshooting step. It does not address the likely network-related cause. B. Increase the RPO interval setting in order to reduce the replication load. This is not a standard first troubleshooting step for replication failure. Increasing RPO might reduce frequency of replication, but it does not solve a connectivity problem. It would also not be the first thing to do when errors suggest a transport issue. D. Perform a test failover at the recovery site. This is a validation activity, not an initial troubleshooting step. If replication is already failing, a test failover could be risky and would not help identify the root cause first. Important note about the provided “correct answer”: Based on the question details, B does not match the most likely root-cause investigation. If this is from a quiz or exam bank, the keyed answer may be wrong, or the question may have been written incorrectly. Best answer from a troubleshooting standpoint: C. Verify required ports are open and reachable between clusters. If you want, I can also help rewrite the question so that the correct answer and the scenario align properly.
Right Answer: B
Quiz
Question 3/103/10
A Veeam backup job is configured to use Nutanix application-consistent snapshots for several Windows VMs. Crash-consistent snapshots succeed, but Veeam reports that application-consistent snapshots fail with errors related to VSS processing. Upon investigation, the administrator confirms: The VMs are powered on. Network connectivity between the backup server and cluster is healthy. Which configuration should the administrator verify to resolve the issue?
Select the answer:Select the answer
1 correct answer
A.
Enable incremental backups on the VMs.
B.
Ensure NGT is installed on the VMs.
C.
Increase the snapshot retention count.
D.
Configure synchronous replication.
The correct answer is B. Ensure NGT is installed on the VMs. Veeam can create crash-consistent snapshots without needing guest OS integration. That is why the backups are succeeding at the crash-consistent level. However, application-consistent snapshots require coordination with the guest operating system, specifically Windows Volume Shadow Copy Service (VSS). In a Nutanix environment, this coordination depends on Nutanix Guest Tools (NGT). NGT provides the integration needed for: - guest quiescing - VSS processing on Windows VMs - application-consistent snapshot support If NGT is not installed, disabled, or not functioning properly, Veeam may be able to take a crash-consistent snapshot but fail when attempting application-consistent processing because VSS cannot be triggered correctly inside the VM. Why the other options are incorrect: A. Enable incremental backups on the VMs - Incremental backup settings do not affect whether VSS-based application-consistent snapshots can be created. C. Increase the snapshot retention count - Snapshot retention affects how long snapshots are kept, not whether VSS processing succeeds. D. Configure synchronous replication - Replication settings are unrelated to guest OS quiescing or VSS integration. Conclusion: Because the failure is specifically tied to VSS processing for application-consistent snapshots, the administrator should verify that Nutanix Guest Tools is installed and working on the Windows VMs.
Right Answer: B
Quiz
Question 4/104/10
What must the maximum Round Trip Latency be less than between a Witness VM and Metro Availability PDs?
Select the answer:Select the answer
1 correct answer
A.
5ms
B.
100ms
C.
200ms
D.
500ms
The correct answer is C. 200ms. In a Metro Availability setup, the Witness VM needs to communicate reliably with the Protected Domains (PDs) to determine site health and support failover decisions. One of the key requirements for this kind of stretched or metro architecture is that network latency must be kept within a defined limit so that the witness can respond quickly enough for quorum and availability operations. The question asks specifically about the maximum Round Trip Latency between a Witness VM and Metro Availability PDs. The required threshold is less than 200 milliseconds. Why the other options are incorrect: - A. 5ms: This is far too low and would be more typical of very tight locality requirements, not the stated maximum. - B. 100ms: Also too low for this specific requirement. - D. 500ms: Too high; latency this large would likely interfere with timely witness communication and availability decisions. So the correct choice is: C. 200ms
Right Answer: C
Quiz
Question 5/105/10
Which log file should an administrator review to ensure consistent connectivity stability between primary and remote disaster recovery sites?
Select the answer:Select the answer
1 correct answer
A.
mantle.out
B.
genesis.out
C.
prism_monitor.INFO
D.
cerebro.INFO
The correct answer is D. cerebro.INFO An administrator who wants to verify consistent connectivity stability between a primary site and a remote disaster recovery site should review the log file related to site coordination, replication, or cluster communication. In this case, cerebro.INFO is the appropriate log because it is associated with the system component responsible for monitoring and maintaining communication between sites. Why D is correct: - cerebro.INFO typically contains information about inter-site communication and synchronization activity. - It can help identify connectivity issues, latency, failures, or instability between the primary and disaster recovery environments. - Reviewing this log helps confirm that the DR link is functioning reliably over time. Why the other options are incorrect: - A. mantle.out: This is not the primary log used for monitoring site-to-site connectivity stability. - B. genesis.out: This log is generally related to startup or initialization processes, not ongoing DR connectivity monitoring. - C. prism_monitor.INFO: This log is more commonly associated with monitoring or health status within the management layer, but not specifically the best source for validating stable connectivity between primary and DR sites. In short, cerebro.INFO is the log most directly tied to checking and troubleshooting connectivity between the primary and remote disaster recovery sites.
Right Answer: D
Quiz
Question 6/106/10
An administrator needs to provide leadership with a report showing the timeframe of each step during Recovery Plan failover testing. How should the administrator produce this report?
Select the answer:Select the answer
1 correct answer
A.
Filter the Events log in Prism Central for Recovery Plan activity.
B.
Review the built-in execution report from the test failover results.
C.
Generate a custom report within Prism Central Intelligent Operations.
D.
Use ncli on a CVM to query Recovery Plan execution history.
The correct answer is B. Review the built-in execution report from the test failover results. When a Recovery Plan failover test is run, the system generates an execution report that includes the details of the test, such as the sequence of steps performed and the timing for each step. This is the most direct and appropriate source for leadership reporting because it is specifically designed to summarize the failover test outcome, including the timeframe of each action. Why B is correct: - The built-in execution report is part of the Recovery Plan test failover results. - It provides a clear, structured view of what happened during the test. - It includes timing information for each step, which is exactly what leadership wants to see. Why the other options are not correct: A. Filter the Events log in Prism Central for Recovery Plan activity. - Event logs can show that actions occurred, but they are not the best source for a step-by-step timeframe report. - Logs are more useful for troubleshooting than for producing a concise management report. C. Generate a custom report within Prism Central Intelligent Operations. - Intelligent Operations reports are useful for broader analytics and custom dashboards, but they are not the standard way to get detailed Recovery Plan step timing. - This would require extra customization and is not the intended feature for this requirement. D. Use ncli on a CVM to query Recovery Plan execution history. - ncli is a command-line tool, which is not ideal for producing a leadership-facing report. - It may provide low-level data, but it is not the built-in reporting method intended for this purpose. In summary: The built-in execution report from the test failover results is the best choice because it directly provides the timeframe and sequence of each step in the Recovery Plan failover test.
Right Answer: B
Quiz
Question 7/107/10
How does Nutanix Disaster Recovery automatically handle Container Mapping if a storage container with the same name does not exist at the recovery Nutanix cluster?
Select the answer:Select the answer
1 correct answer
A.
The data is temporarily kept in the SSD tier of the remote site pending intervention.
B.
The system automatically creates a new Storage Container with the same name on the remote site.
C.
The initial replication fails and generates a critical alert requiring manual mapping in Prism Central.
D.
The recovery points replicate to a random storage container at the recovery Nutanix cluster.
The correct answer is B. The system automatically creates a new Storage Container with the same name on the remote site. In Nutanix Disaster Recovery, container mapping is used to match the source storage container at the protected site with a corresponding container at the recovery site. If a storage container with the same name does not already exist on the recovery Nutanix cluster, Nutanix DR handles this automatically by creating a new storage container with the same name on that remote cluster. Why this is correct: - Nutanix DR is designed to simplify replication and recovery setup. - During protection plan configuration, the system ensures that the required storage container exists on the recovery side. - If it is missing, the system creates it automatically rather than forcing manual intervention. Why the other options are incorrect: - A. Temporary SSD tier storage is not how Nutanix DR handles missing container mapping. - C. Replication does not fail just because the container is missing; Nutanix DR automates the mapping. - D. Recovery points are not placed into a random storage container; mapping is explicit and controlled. Key takeaway: Nutanix Disaster Recovery automates container mapping by creating a matching container on the recovery cluster when one does not already exist, which reduces administrative effort and helps ensure recovery readiness.
Right Answer: B
Quiz
Question 8/108/10
An administrator finds replications for Marketing VMs are failing to replicate. After doing some digging the administrator was able to find the following: Connectivity was confirmed on ports 2020 and 2009 between the clusters All other VMs are replicating successfully Cluster wide storage has plenty of remaining space No firewall exists between the sites Marketing VMs are running Windows, successful VMs are running Linux What could be causing the Marketing VMs to fail replications?
Select the answer:Select the answer
1 correct answer
A.
Linux VMs are set up with a container mapping on the remote site.
B.
Marketing VMs are replicating using Async instead of NearSync.
C.
Marketing VMs are replicating to a container with zero free space.
D.
Linux VMs are replicating using Async instead of NearSync.
The correct answer is A. Linux VMs are set up with a container mapping on the remote site. Here is why: The key clue is that only the Marketing VMs are failing, while other VMs replicate successfully. That means the issue is specific to those VMs or to how they are configured, not to the overall cluster, network, or replication service. Let’s review the evidence: - Connectivity on ports 2020 and 2009 is confirmed This indicates that the replication communication path between clusters is working. - All other VMs are replicating successfully This rules out a general replication outage, cluster-wide networking problem, or a system-wide storage issue. - Cluster-wide storage has plenty of remaining space So capacity is not the problem. - No firewall exists between the sites This further rules out network blocking. - Marketing VMs are running Windows, successful VMs are running Linux This is the most important clue. In many hyperconverged or replication environments, Linux VMs may be associated with a container mapping on the remote site, while Windows VMs may require a different replication configuration or may not inherit the same remote container mapping behavior. If the remote site does not have the proper container mapping for the Marketing VMs, replication can fail even though everything else appears healthy. Why the other options are not correct: B. Marketing VMs are replicating using Async instead of NearSync. This is unlikely to be the cause because replication mode mismatch would typically affect configuration compatibility or recovery objectives, not only one set of Windows VMs while Linux VMs work fine. Also, the problem statement does not indicate a replication mode issue. C. Marketing VMs are replicating to a container with zero free space. If the target container had zero free space, other VMs targeting the same destination would likely also fail. Since all other VMs are replicating successfully, this is not consistent. D. Linux VMs are replicating using Async instead of NearSync. This does not explain why the Windows Marketing VMs fail while Linux VMs succeed. It also points to the wrong VM type. Best conclusion: The failure is most likely due to a container mapping problem on the remote site for the Marketing Windows VMs, which is why A is correct. If you want, I can also explain what container mapping means in this context and why it affects replication.
Right Answer: A
Quiz
Question 9/109/10
A company's two clusters are part of the same availability zone. Prism Central, which holds the protection policy configuration and recovery plans, is located on Cluster A and protected by the Prism Central Backup and Restore mechanism. What is the first step to take to execute a disaster recovery plan on the datacenter hosting Cluster A?
Select the answer:Select the answer
1 correct answer
A.
Restore the Prism Central instance from Prism Element on the surviving cluster.
B.
Deploy a new Prism Central instance on the surviving cluster and register the cluster to it to access the replicated VM snapshots.
C.
Log into Prism Element on the surviving cluster and execute the Recovery Plan.
D.
Access the Prism Central web interface via its Floating IP to trigger the "Unplanned Failover" workflow for the affected VMs.
The correct answer is A. Restore the Prism Central instance from Prism Element on the surviving cluster. In this scenario, Prism Central is located on Cluster A, and Cluster A is the datacenter that has failed. Since Prism Central contains the protection policies and recovery plans, those plans are no longer accessible if Prism Central is down. Because Prism Central itself is protected by Prism Central Backup and Restore, the first step in a disaster recovery situation is to restore Prism Central on the surviving cluster using its backup. Once Prism Central is restored, you regain access to the recovery plans and can continue with the failover or recovery workflow for the protected workloads. Why the other options are incorrect: B. Deploy a new Prism Central instance on the surviving cluster and register the cluster to it to access the replicated VM snapshots. This is not the first step. A new Prism Central deployment would not automatically restore the existing recovery plans and protection policy configuration. The correct action is to restore the backed-up Prism Central instance. C. Log into Prism Element on the surviving cluster and execute the Recovery Plan. Recovery plans are managed in Prism Central, not directly executed from Prism Element. Without restoring Prism Central first, the recovery plan is not available. D. Access the Prism Central web interface via its Floating IP to trigger the "Unplanned Failover" workflow for the affected VMs. If Cluster A is down, Prism Central hosted there is unavailable. The Floating IP cannot be used if the underlying site is failed. Also, the recovery workflow depends on Prism Central being restored and available. Summary: Since Prism Central hosts the recovery plans and is itself lost with Cluster A, the first step is to restore Prism Central from backup on the surviving cluster. After that, the disaster recovery plan can be executed.
Right Answer: A
Quiz
Question 10/1010/10
After a failover and stabilization of workloads at the recovery AZ, an administrator removes several VMs from the protection policy because they are no longer required. Which action should be performed as part of post-failover cleanup to prevent unnecessary storage consumption?
Select the answer:Select the answer
1 correct answer
A.
Recreate the recovery plan.
B.
Reconfigure the replication schedule.
C.
Delete the associated recovery points.
D.
Disable Nearsync replication.
The correct answer is B. Reconfigure the replication schedule. After a failover, some workloads may no longer need to remain protected. If the administrator removes those VMs from the protection policy, the replication settings may still retain old replication behavior or continue allocating storage resources for data that is no longer needed. Reconfiguring the replication schedule ensures the protection configuration reflects the updated workload set, which helps stop unnecessary replication activity and reduces avoidable storage consumption. Why the other options are not correct: A. Recreate the recovery plan. This is unnecessary. A recovery plan is used to orchestrate failover and failback, but recreating it is not the right cleanup step for removing no-longer-needed VMs. C. Delete the associated recovery points. Recovery points are important for recovery history and rollback options. Deleting them is not the standard first action for post-failover cleanup, and it may remove useful recovery data prematurely. D. Disable Nearsync replication. This is too specific and not generally the correct post-failover cleanup action. Disabling Nearsync is only appropriate if the environment explicitly uses that feature and it is no longer needed. Why B is best: Reconfiguring the replication schedule aligns the replication setup with the reduced protection scope after failover. It prevents the system from continuing to generate and retain replication data for VMs that have been removed from the policy, which helps avoid unnecessary storage usage.
NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Practice test unlocks all online simulator questions
Thank you for choosing the free version of the NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 practice test! Further deepen your knowledge on Nutanix Simulator; by unlocking the full version of our NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Simulator you will be able to take tests with over 109 constantly updated questions and easily pass your exam. 98% of people pass the exam in the first attempt after preparing with our 109 questions.
What to expect from our NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 practice tests and how to prepare for any exam?
The NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Simulator Practice Tests are part of the Nutanix Database and are the best way to prepare for any NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 exam. The NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 practice tests consist of 109 questions and are written by experts to help you and prepare you to pass the exam on the first attempt. The NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 database includes questions from previous and other exams, which means you will be able to practice simulating past and future questions. Preparation with NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Simulator will also give you an idea of the time it will take to complete each section of the NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 practice test . It is important to note that the NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Simulator does not replace the classic NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 study guides; however, the Simulator provides valuable insights into what to expect and how much work needs to be done to prepare for the NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 exam.
NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Practice test therefore represents an excellent tool to prepare for the actual exam together with our Nutanix practice test . Our NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Simulator will help you assess your level of preparation and understand your strengths and weaknesses. Below you can read all the quizzes you will find in our NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Simulator and how our unique NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Database made up of real questions:
Info quiz:
Quiz name:NCP-BC: Nutanix Certified Professional - Business Continuity v7.5
Total number of questions:109
Number of questions for the test:50
Pass score:80%
You can prepare for the NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 exams with our mobile app. It is very easy to use and even works offline in case of network failure, with all the functions you need to study and practice with our NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Simulator.
Use our Mobile App, available for both Android and iOS devices, with our NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Simulator . You can use it anywhere and always remember that our mobile app is free and available on all stores.
Our Mobile App contains all NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 practice tests which consist of 109 questions and also provide study material to pass the final NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 exam with guaranteed success.
Our NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 database contain hundreds of questions and Nutanix Tests related to NCP-BC: Nutanix Certified Professional - Business Continuity v7.5 Exam. This way you can practice anywhere you want, even offline without the internet.